Clean Burn Maintenance
Annual Preventative Maintenance of Clean Burn Used Oil Furnace
1. Unit should be vacuum cleaned
- A. CB1400, every 500 hours
- B. All other units, 700 hours
- C. Burner is recommended for block flushing at 3000 hours
2. Smoke pipe should be taken apart and cleaned
3. ll oil filters cleaned, check valve cleaned and flushed.
4. Burner should be reconditioned
- A. Heater block cleaned and flushed (Every 2500 Hrs.)
- B. Heaters removed and cleaned
- C. Air and oil regulators removed and cleaned
- D. Cad cell, relay, transformer and motors checked
5. New electrodes installed
6. Nozzle cleaned or replaced
7. Unit fired and adjusted
8. Draft regulator set to maintain .02 over fire
Preventive Maintenance Service Kits
| Furnace Model |
Part # |
| (AA)- (86AH&BH)- (90AH&BH) |
96-525 |
|
|
| Burner Models |
|
| 500 |
96-526 |
| 525(s) |
96-967 |
| 525(S2) |
96-935 |
| 350(S2) |
96-935 |
|